Low Temperature Plasma Sterilizers

STERRAD™ Low-Temperature Hydrogen Peroxide Gas Plasma Sterilizers can ensure safe sterilization of a range of medical devices for busy operating rooms, whilst minimising workflow interruptions and improving productivity.

Check how Advanced Sterilization Product’s STERRAD™ Low-Temperature Hydrogen Peroxide Gas Plasma Sterilizers can help ensure your staff safely meet the demands of the busy operating rooms on time, every time.

Reduce workflow interruptions and improve productivity with built-in ALLClear™ Technology™, which conditions the load, checks for moisture and runs system diagnostics, prior to sterilization cycles, thus increasing productivity. With STERRAD™ Systems, users can benefit from additional cycle types and features through software upgrades, without the need to purchase a new machine. An internal ultraviolet (UV) lamp ensures accurate hydrogen peroxide monitor measurements by providing a stable UV light source.

Compare STERRAD™ Systems below

STERRAD-Systems 100NX

STERRAD™ 100NX System with ALLClear™ Technology

STERRAD-Systems

STERRAD NX™ System with ALLClear™ Technology

Express1

Flex1

Standard1

Duo

 

24

42

47

60

 

Cycles

Standard1

Advanced1

 

 

 

28

38

 

 

 

152L (5.4 ft3)
20.7” W x 28.9” D x 20.1” H
Chamber size
51. 3 L (1.8 ft3)
12.6” W x 23.6” D x 6.2” H
YES
Capable of processing flexible endoscopes
YES
YES
Capable of processing DaVinci® endoscopes
 
YES
Hydrogen peroxide monitor
YES
YES
Moisture detection & correction
YES
YES
Instrument warming
YES
YES
System Check Self-Diagnostics
YES
YES
Electronic data storage
YES
YES
Network connectivity
YES
YES
bar code scanner
YES
YES
Foot pad for hands-free operation
 
YES
Point of use guidance to reduce human error
YES
YES
Integrates with ASP ACCESS™ Technology for additional automation, reporting, trends and alert data, and tablet/smartphone compatibility
YES
YES
Double-door configuration for pass-through workflows
 
Cabinet, Recessed
Configuration
Countertop, Cart
Electricity
Utilities needed
Electricity
YES
STERRAD Velocity™ Biological Indicator/Process Challenge Device at BI/PCD 15 minute time to result2
YES
STERRAD-Systems-2-1
STERRAD-Systems-2-2

STERRAD™ 100NX System with ALLClear™ Technology

STERRAD NX™ System with ALLClear™ Technology

Cycles

Express1

Flex1

Standard1

Duo

 

24

42

47

60

 

Standard1

Advanced1

 

 

 

28

38

 

 

 

Chamber size

152L (5.4 ft3)
20.7” W x 28.9” D x 20.1” H

51. 3 L (1.8 ft3)
12.6” W x 23.6” D x 6.2” H

Capable of processing flexible endoscopes

YES

YES

Capable of processing DaVinci® endoscopes

YES

 

Hydrogen peroxide monitor

YES

YES

Moisture detection & correction

YES

YES

Instrument warming

YES

YES

System Check Self-Diagnostics

YES

YES

Electronic data storage

YES

YES

Network connectivity

YES

YES

Optional bar code scanner

Yes

YES

Foot pad for hands-free operation

YES

 

Point of use guidance to reduce human error

YES

YES

Integrates with ASP ACCESS™ Technology for additional automation, reporting, trends and alert data, and tablet/smartphone compatibility

YES

YES

Double-door configuration for pass-through workflows

YES

 

Configuration

Cabinet, Recessed

Countertop, Cart

Utilities needed

Electricity

Electricity

STERRAD Velocity™ Biological Indicator/Process Challenge Device at BI/PCD 15 minute time to result2

YES

YES

100NX angled view

STERRAD Systems’ newest platform, the STERRAD™ 100NX System with ALLClear™ Technology features over 25 years of innovation in hydrogen peroxide gas plasma sterilization technology, enabling sterilization of a variety of medical devices.

Phoenix - STERRAD NX-clear

The STERRAD NX™ System with ALLClear™ Technology ensures the same level of safety, whilst providing a compact, portable™ option.

Get a quote or consultation for STERRAD™ Systems exclusive hydrogen peroxide gas plasma sterilization technology today.

  1. Cycle times are approximate. ALLClear™ Technology may increase processing time by approximately 5 minutes.
  2. 15 or 30 minutes dependent on software version. Refer to the IFU for actual time to results.
  3. The research was designed and executed by Actionable Research, an independent third-party research firm in conjunction with ChemDAQ™ Inc., a manufacturer of environmental safety monitoring systems. The research sponsor was Advanced Sterilization Products. All data were collected by the ChemDAQ™ staff

The third-party trademarks used herein are the properties of their respective owners.

AD-230024-01-CT_A-MDR

Disclaimer

The content of this website is aimed exclusively at healthcare professionals (HCPs) and not at the general public. Please confirm by clicking below that you are a healthcare professional, duly authorized to practice in your field. ASP EMEA declines all responsibility in case of unauthorized consultation.