Reduce workflow interruptions with the ALLClear™ Technology in the STERRAD™ Systems, which increases productivity by conditioning the load, checking for moisture, and running system diagnostics prior to sterilization cycles. With STERRAD™ Systems, customers are able to add cycles and features via purchase of software upgrades - without the need to buy a new machine. An internal UV lamp provides a stable UV light source for the Hydrogen Peroxide Monitor resulting in accurate measurements.
Compare STERRAD™ Systems below
STERRAD™ 100NX System with ALLClear™ Technology
STERRAD NX™ System with ALLClear™ Technology
Express1 Flex1 Standard1 Duo
24 42 47 60
|
Cycles
|
Standard1 Advanced1
28 38
|
152L (5.4 ft3) 20.7” W x 28.9” D x 20.1” H |
Chamber size
|
51. 3 L (1.8 ft3) 12.6” W x 23.6” D x 6.2” H |
YES |
Capable of processing flexible endoscopes
|
YES |
YES |
Capable of processing DaVinci™ endoscopes
|
|
YES |
Hydrogen peroxide monitor
|
YES |
YES |
Moisture detection & correction
|
YES |
YES |
Instrument warming
|
YES |
YES |
System Check Self-Diagnostics
|
YES |
YES |
Electronic data storage
|
YES |
YES |
Network connectivity
|
YES |
YES |
bar code scanner
|
YES |
YES |
Foot pad for hands-free operation
|
|
YES |
Point of use guidance to reduce human error
|
YES |
YES |
Integrates with ASP ACCESS™ Technology for additional automation, reporting, trends and alert data, and tablet/smartphone compatibility
|
YES |
YES |
Double-door configuration for pass-through workflows
|
|
Cabinet, Recessed |
Configuration
|
Countertop, Cart |
Electricity |
Utilities needed
|
Electricity |
YES |
STERRAD Velocity™ Biological Indicator/Process Challenge Device at BI/PCD 15 minute time to result2
|
YES |
STERRAD™ 100NX System with ALLClear™ Technology
STERRAD NX™ System with ALLClear™ Technology
Cycles
Express1
Flex1
Standard1
Duo
24
42
47
60
Standard1
Advanced1
28
38
Chamber size
152L (5.4 ft3)
20.7” W x 28.9” D x 20.1” H
51. 3 L (1.8 ft3)
12.6” W x 23.6” D x 6.2” H
Capable of processing flexible endoscopes
YES
YES
Capable of processing DaVinci™ endoscopes
YES
Hydrogen peroxide monitor
YES
YES
Moisture detection & correction
YES
YES
Instrument warming
YES
YES
System Check Self-Diagnostics
YES
YES
Electronic data storage
YES
YES
Network connectivity
YES
YES
Optional bar code scanner
Yes
YES
Foot pad for hands-free operation
YES
Point of use guidance to reduce human error
YES
YES
Integrates with ASP ACCESS™ Technology for additional automation, reporting, trends and alert data, and tablet/smartphone compatibility
YES
YES
Double-door configuration for pass-through workflows
YES
Configuration
Cabinet, Recessed
Countertop, Cart
Utilities needed
Electricity
Electricity
STERRAD Velocity™ Biological Indicator/Process Challenge Device at BI/PCD 15 minute time to result2
YES
YES
STERRAD™ 100NX System with ALLClear™ Technology is one of the latest releases from the STERRAD™ Systems platform, featuring over 25 years of innovation in hydrogen peroxide gas plasma (HPGP) sterilization technology.
STERRAD NX™ System with ALLClear™ Technology STERRAD NX™ System with ALLClear™ Technology is the compact unit from the STERRAD™ Systems platform.
1Cycle times are approximate. ALLClear™ Technology may increase processing time by approximately 5 minutes.
215 or 30 minutes dependent on software version. Refer to the IFU for actual time to results.
3The research was designed and executed by Actionable Research, an independent third-party research firm in conjunction with ChemDAQ® Inc., a manufacturer of environmental safety monitoring systems. The research sponsor was Advanced Sterilization Products. All data were collected by the ChemDAQ® staff
The third-party trademarks used herein are the properties of their respective owners.